Retrofit Kit - Generic Pulse Count Sensor

$850.00
| /
description

The Generic Pulse Count Sensor Kit, also referred to as a Flow Meter Retrofit Kit, includes a pulse count loom and INCYT Blue Node to connect to a compatible pulse output on an existing flow meter, bringing water-use data into the INCYT platform. One sensor reads flow rate, flow volume and an accumulated meter reading to allow for planning around pump time, account for unexpected changes in flow and gather data to monitor water delivery. 


WHAT'S INCLUDED
- 1 x INCYT Pulse Count Loom
- 1 x INCYT Blue Node
- Zip ties for securing the cable run
- Silicon to waterproof the connector 
- Access to your data on the INCYT platform


- CONNECTIVITY
The pulse count loom connects the meter’s pulse output to the Blue Node. The Blue Node is a battery pack and telemetry device for your sensor which transmits readings through the INCYT XR Network Base Station, to the Cockpit on your phone, tablet or computer. Because the network is yours, you are not dependent on mobile coverage; the sensor only needs to be within range of your Base Station, so it can sit in a paddock, pump shed or remote corner of the property even where 4G and 5G do not reach. A single Base Station connects hundreds of devices, so every sensor you add after the first runs on infrastructure you already have. For more information on connectivity, click here.


- MEASUREMENT
Each pulse represents a known volume of water passing through the meter. The meter’s litres-per-pulse value is entered in the INCYT app so pulse counts can be converted into water volume. Flow rate is calculated from the volume recorded over time. The loom listens to the meter’s output and does not supply power to the meter.


- YOUR DATA AND CUSTOM ALARMS
In the Cockpit you can see flow rate and volume data across different periods, from 24 hours to a week to a year, and set low and high flow alarms. Alarms can be configured against a specific quantity of water over a custom period, for example less than 5ML in a 12 hour period, which then triggers an email, SMS or in-app message once the threshold is met. That accumulation against a period is how you manage an allocation rather than just observe a flow.


- INSTALLATION AND COMPATIBILITY
Confirm the meter model, pulse output and litres-per-pulse setting before installation. The PCL10 supports suitable dry-contact, reed-switch and NPN open-collector or open-drain outputs. The input must never exceed 3.3 V; active 5 V, 12 V or 24 V pulse outputs must not be connected directly. Keep the cable splice off the ground and protected from submersion or burial.

Where a meter enclosure is sealed or tagged, arrange the connection through the meter’s authorised installer or DQP, as applicable, and confirm the permitted connection arrangement before work begins.