Floodplain Harvesting - Secondary Measurement Device
An ultrasonic water level sensor; approved as a Secondary Measurement Device under the NSW Government's Floodplain Harvesting Compliance program. An approved secondary device is the recognised back-up to your primary metering equipment. With two kits available; with or without INCYT's Base Station, getting compliant is now easier than ever. You can keep harvesting when your primary meter is faulty or not yet installed. The infrastructure you bought for compliance is then immediately reusable for channel levels, dam levels and tailwater returns, so a regulatory cost becomes the foundation of your irrigation monitoring.
WHAT'S INCLUDED
- 1 x Ultrasonic water level sensor
- 1 x INCYT Blue Node
- Sensor-to-Blue-Node connecting cable
- Zip ties for securing the cable run
- Access to your data on the INCYT platform
- Optional addition: 1 x XR Network Base Station kit (solar powered, with antenna cable and mounting hardware) with a free radio-frequency mapping session before installation to position the Base Station
HOW IT WORKS
- CONNECTIVITY
This sensor reports to the INCYT Cockpit over INCYT's XR Network: a proprietary long-range, low-power network that you run yourself on your own property. The sensor pairs with an INCYT Blue Node, the Blue Node is a battery pack and telemetry device for your sensor which transmits readings through the INCYT XR Network Base Station, to the Cockpit on your phone, tablet or computer. Because the network is yours, you are not dependent on mobile coverage; the sensor only needs to be within range of your Base Station, so it can sit in a paddock, storage or remote corner of the property even where 4G and 5G do not reach. A single Base Station connects hundreds of devices, so every sensor you add after the first runs on infrastructure you already have. For more information on connectivity, click here.
- MEASUREMENT
The sensor is mounted above the water and fires an ultrasonic pulse at the surface, timing the returning echo to calculate the distance down to the water. Against the profile you have configured, that distance becomes a live depth, volume and percentage-full reading. Nothing is immersed, so there is no element in the water to be fouled by silt, weed or debris. Maximum measurable depth is 8 metres and the sensor must be mounted at least 55cm above the maximum water level.
- YOUR DATA & CUSTOM ALARMS
In the Cockpit you can see the current storage fill level and how it has changed over days and weeks. Alarms can be set when a level is reached, expressed as a percentage of capacity, a volume or a depth; when volume drawn over a nominated period exceeds a set amount; or when the level rises by more than a set amount within a set time. Once the Base Station (if selected) is installed it can receive data from hundreds of other sensors within range depending on topography, so the same infrastructure covers the rest of your assets.
- INSTALLATION
Under NSW Floodplain Harvesting rules, any Secondary Measurement Device, including this one, must be installed and validated by a Duly Qualified Person (DQP) who holds the Certified Storage Meter Installer & Validator credential.
The sensor, Blue Node and bracket are mounted at the point of measurement, and the Base Station (if selected) is mounted wherever gives the best XR Network coverage across your property. INCYT will establish that position with you in a free radio-frequency mapping session. Mounting the sensor can be to existing infrastructure, to a structure you build, or to an INCYT frame designed to suit most storage structures.
- ADDITIONAL INFO
As the NSW Government rolls out the Floodplain Harvesting Compliance program across the Murray-Darling Basin, INCYT's ultrasonic water sensor and its accompanying telemetry devices have been approved as a Secondary Measurement Device. A secondary device is your back-up system, and it allows you to floodplain harvest if your primary metering equipment is faulty, or before the primary metering equipment rollout date, which falls 12 months from water being credited to your floodplain harvesting access licence account. Refer to the NSW Government guidance on Secondary Metering Devices before ordering.